A section view of horizontal Architectural Wall Panels (AWP) on prefab/modular units meeting at a horizontal unit joint. AWP are installed offsite and are jointed onsite with a specialized horizontal/compression joint.
A section view of horizontal Architectural Wall Panels (AWP) on prefab/modular units meeting at a horizontal unit joint. AWP are mainly installed offsite and jointed onsite utilizing a horizontal/compression joint with a field-installed, infill course.
A plan view of horizontal Architectural Wall Panels (AWP) on prefab/modular units meeting at a vertical unit joint and inside corner. AWP are installed offsite.
A plan view of horizontal Architectural Wall Panels (AWP) on prefab/modular units meeting at a vertical unit joint. AWP are installed offsite with vertical edges at the unit joints capped by J-Mold trim.
A plan view of horizontal Architectural Wall Panels (AWP) on prefab/modular units meeting at a vertical unit joint. AWP are mainly installed offsite and jointed onsite utilizing field-installed, infill panels. The overall panel layout is stacked bond.
A plan view of horizontal Architectural Wall Panels (AWP) on prefab/modular units meeting at a vertical unit joint. AWP are mainly installed offsite and jointed onsite utilizing field-installed, infill panels. The overall panel layout is staggered bond.
A section view of vertical Architectural Wall Panels (AWP) on prefab/modular units meeting at a horizontal unit joint. AWP are installed offsite and are jointed onsite with a specialized horizontal/compression joint. A continuous insulation and furring grid assembly are depicted.
A section view of vertical Architectural Wall Panels (AWP) on prefab/modular units meeting at a horizontal unit joint. AWP are primarily installed offsite and are jointed onsite with a band of field-installed infill panels.
A plan view of vertical Architectural Wall Panels (AWP) on prefab/modular units meeting at a vertical unit joint. AWP are installed offsite with vertical edges at the unit joints capped by J-Mold trim. A continuous insulation and furring grid assembly are depicted.
A plan view of vertical Architectural Wall Panels (AWP) on prefab/modular units meeting at a vertical unit joint. AWP are mainly installed offsite and jointed onsite utilizing field-installed, infill panels and a vertical control/expansion (sealant) joint. Continuous insulation and a furring grid are depicted.
Within the drafting view of this file you can access any detail needed for horizontal panels on a stud wall with continuous insulation
Within the drafting view of this file you can access any detail needed for horizontal panels on a cmu wall with no continuous insulation
Within the drafting view of this file you can access any detail needed for vertical panels on a cmu wall with continuous insulation
Within the drafting view of this file you can access any detail needed for vertical panels on a cmu wall with no continuous insulation
Within the drafting view of this file you can access any detail needed for vertical panels on a stud wall with continuous insulation